UPS ATLANTIS A03-OP2002-RC 2000VA, 1350W RACK 2U -DOPPIA CONVERS.SMART BATT.MANAG.INTERF.EPO-3 BATT.12V, 9A (SOST.A03-OP2001-RC)
Disponibilità: ultimi pezzi rimasti
505,47 €
UPS ATLANTIS A03-OP2002-RC 2000VA 1350W RACK 2U -DOPPIA CONVERS. SMART BATT. MANAG. INTERF. EPO-3 BATT. 12V 9A SOST. A03-OP2001-RC Power ...
UPS ATLANTIS A03-OP2002-RC 2000VA/1350W RACK 2U -DOPPIA CONVERS.SMART BATT.MANAG.INTERF.EPO-3 BATT.12V/9A (SOST.A03-OP2001-RC)
Power Rating (VA): 2000
Power Rating (W): 1350
Input (Low Line Transfer):
- 80VAC-300VAC (load <=30%±5%)
- 120VAC-300VAC (load <=60%±5%)
- 140VAC-300VAC (load <=80%±5%)
- 160VAC-300VAC (load <=100%±5%)
Frequency Range: 40Hz to 70Hz
Power Factor: >0,99 (Normal Voltage)
Output
- Voltage: 208/220/230/240VAC
- AC Voltage Regulation: ±1%
- Frequency Range: 50Hz (±0.5%) or 60Hz (±0.5%)
- Waveform: Pure SineWave
- Crest Ratio: 3:1 (Max)
- Harmonic Distortion: <3% THD (liner Load) | <5% THD (Non liner Load)
Transfer:
- AC->Battery: Zero
- INV->ByPass: Less than 4ms (typical)
WaveForm (Batt. Mode): Pure Sinewave
Efficiency:
- AC Mode = 89%
- Battery = 85%
- ECO = 97%
Battery
- Voltage: 36VDC
- Capacity: 12V/9.0Ah
- Quantity: 3
- Recharge Time: 4 hours to (90%)
- Type: Sealed Maintenance Free Lead Acid VRLA Type
- Design: Easy-swappable battery design
- Charging Voltage: 41,1VDC ±1%
- Charging I: 1.0A Max
Indicators LCD Display
- UPS status | Load level | Battery level | Input/Output/battery info | Discharge time and Fault indicators
Backup Times:
- 1350w up to 2:30m
- 1013w up to 5:30m
- 675w up to 9 m
- 338w up to 22m
Protection:
- 105% < Overload AC <110% Overload Warning Only
- 110% < Overload AC <130% Overload Warning UPS transfers to ByPass after 1 minutes
- Overload AC >130% Overload Warning UPS transfers to ByPass after 3 seconds
- 105% < Overload Battery <110% Overload Warning Only
- 110% < Overload Battery <130% Overload Warning UPS shut down after 1 minute
- Overload AC >130% Overload Warning shut down after 3 seconds
- 110% < ByPass <120% Overload Warning UPS shut down after 30 minutes
- 120% < ByPass <130% Overload Warning UPS shut down after 10 minutes
- ByPass >130% Overload Warning UPS shut down after 1 minute
- Overload Inverter (>100%)
- Short Circuit INV: Electric Circuit
- Short Circuit AC: ICB & Electric Circuit
- Battery Over-drain Two stages: Controlled Battery Low Warning & Cut Off
- High Surge Level Immunity (>7KV)
Advanced:
- Fan detect protection and Fan speed control
- ECO mode
Connections
- Output 8xIEC 320 C13 (Battery Power Supplied)
- RS232 and USB (HID)
- Intelligent Slot for SNMP Card
- EPO / ROO
Dimensions (WxHxD): 438 x 88 x 450 mm
Net Weight 14,0 Kg (with Battery)
Temperature: 0°-40° C
Humidity: 20-90% (non-condensing)
Ci impegnamo costantemente ad aggiornare le schede dei prodotti che trovi in questo portale ma, utilizzando anche sistemi automatici per la gestione delle disponibilità ed affini alle schede del prodotto, a volte queste ultime possono non essere precise. Non rilasciamo alcuna garanzia né dichiarazione in relazione all'accuratezza delle informazioni. Se hai bisogno di maggiori info, prima dell'acquisto, ti invitiamo a contattarci da questa pagina così da offrirti ogni informazione che cerchi. Le immagini possono non rispecchiare il reale prodotto che riceverai.