UPS ATLANTIS A03-OP1002 1000VA/900W DOPPIA CONVERS.,SMART BATT.MANAG.INTERFACCIA USB/EPO -2 BATT. 12V/9A (SOST.A03-OP1001)


Power Rating (VA): 1000
Power Rating (W): 900


Input:
- 110VAC-300VAC (load <=50%±5%)
- 140VAC-300VAC (load <=70%±5%)
- 160VAC-300VAC (load <=80%±5%)
- 180VAC-300VAC (load <=100%±5%)
Frequency Range: 40Hz to 70Hz
Power Factor: >0,99 (Normal Voltage)


Output:
- Voltage: 208/220/230/240VAC
- AC Voltage Regulation: ±1% 
- Frequency Range: 50Hz (±0.5%) or 60Hz (±0.5%)
- Waveform: Pure SineWave
- Crest Ratio Current 3:1 (Max)
- Harmonic Distortion (THDU): min 3% THD (liner Load) / min 6% THD (Non liner Load)


Transfer:
- AC->Battery: Zero
- INV->ByPass: Less than 4ms (typical)
WaveForm (Batt. Mode): Pure Sinewave


Efficiency:
- AC Mode = 89%
- Battery = 85%
- ECO = 95%


Battery:
- Voltage: 24VDC
- Capacity: 12V/9.0Ah
- Quantity: 2
- Recharge Time: 4 hours to (90%)
- Type: Sealed Maintenance Free Lead Acid VRLA Type
- Design: Swappable battery design
- Charging Voltage: 27,4VDC ±1%
- Charging Current: 1.0A Max


Indicators (display LCD):
- UPS status, Load level, Battery level, Input/Output/battery info, Discharge time and Fault indicators


Backup Time:
- 900w up to 2:30m
- 675w up to 5:30m
- 450w up to 9 m
- 225w up to 22m


Protection:
- 105% < Overload AC < 110% Overload Warning UPS.Transfer to Bypass after 10 minutes
- 110% < Overload AC < 130% Overload Warning UPS. Transfers to ByPass after 1 minute
- Overload AC > 130% Overload Warning UPS transfers to ByPass after 3 seconds
- 105% < Overload Battery <110% Overload Warning UPS, shut down after 10 minutes
- 110% < Overload Battery <130% Overload Warning UPS shut down after 1 minute
- Overload AC >130% Overload Warning shut down after 3 seconds
- 110% < ByPass <120% Overload Warning UPS shut down after 30 minutes
- 120% < ByPass <130% Overload Warning UPS shut down after 10 minutes
- ByPass > 130% Overload Warning UPS shut down after 1 minute
- Overload Inverter (>100%)
- Short Circuit INV: Electric Circuit
- Short Circuit AC: ICB & Electric Circuit
- Battery Over-drain Two stages: Controlled Battery Low Warning & Cut Off
- High Surge Level Immunity (>7KV)
Advanced: Fan detect protection and Fan speed control | ECO mode


Connections:
- Output 4xIEC 320 C13 (Battery Power Supplied)
- RS232 and USB(HID)
- Intelligent Slot for SNMP Card
- EPO/ROO


Dimensions (WxHxD): 140 x 191 x 327 mm
Net Weight 10,1 Kg (with Battery)
Temperature: 0°-40° C
Humidity: Humidity 20-90% (non-condensing)
Noise level: Less then 50 dBA @ 1.0 meter (battery full charged, without buzzer)

Aggiungi al carrello

Richiedi info o prenota

Ci impegnamo costantemente ad aggiornare le schede dei prodotti che trovi in questo portale ma, utilizzando anche sistemi automatici per la gestione delle disponibilità ed affini alle schede del prodotto, a volte queste ultime possono non essere precise. Non rilasciamo alcuna garanzia né dichiarazione in relazione all'accuratezza delle informazioni. Se hai bisogno di maggiori info, prima dell'acquisto, ti invitiamo a contattarci da questa pagina così da offrirti ogni informazione che cerchi. Le immagini possono non rispecchiare il reale prodotto che riceverai.